72
-
When frost forms on the OU, the heating performance will decrease.
This will cause the unit to automatically switch to defrost operation, and
hot air will stop blowing out from the IO.
The message “In operation for defrosting.” will be displayed on the
message display. After the defrost operation has completed, “In
operation for defrosting.” will disappear, and the unit will switch back to
its normal heating operation.
■
“In operation for defrosting.” display
Menu
Direction
Heating
20
:
20 (Tue)
F1: High power
F2: Energy-saving
Timer
In operation for defrosting.
Set temp
To prevent any cold air blowing out from the IO at the start of a heating
operation, the unit stops the fan and displays “In operation for heating
standby.” on the message display.
When the unit is ready to blow out hot air, the message “In operation for
heating standby.” disappears, and the unit will start heating operation.
■
“In operation for heating standby.” displayed
Menu
Direction
Heating
20
:
20 (Tue)
F1: High power
F2: Energy-saving
Timer
In operation for heating standby.
Set temp
When you select to enable warming up by the Set ON timer by hour (
☞
page 41) or Set ON timer by clock (
☞
page 43), the operation will
start 50 to 60 minutes earlier, which is predicted based on the previous
warm up operation, so that the room will be close to the set temp by the
time it reaches the operation start time.
During the warm up operation, the message “In operation for warming
up.” will be displayed on the message display.
This message will disappear at the time set for operation start.
■
“In operation for warming up.” display
Menu
Direction
Cooling
20
:
20 (Tue)
F1: High power
F2: Energy-saving
ON
In operation for warming up.
Set temp