8 - 7
8 AUXILIARY AND APPLIED FUNCTIONS
(5) Forced output bit
(a) Set the "forced output bit" when you want to forcibly provide the limit switch
outputs during operation.
1) The following control is exercised.
Forced output bit
Control description
Without setting
OFF
Limit switch outputs are turned ON/OFF on the
basis of the "output enable/disable bit" and ON
region setting (ON Value, OFF Value).
With setting
ON
Limit switch outputs are turned ON.
(b) Usable devices
Item
Device No. setting range
Input relay
X0 to X1FFF
Output relay
Y0 to Y1FFF
Internal relay
M0 to M8191
Latch relay
L0 to L8191
Link relay
B0 to B1FFF
Annunciator
F0 to F2047
Special relay
M9000 to M9255
Summary of Contents for Q172CPU
Page 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Page 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Page 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Page 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Page 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...