5 - 29
5 POSITIONING DEDICATED SIGNALS
(6) Servo error reset command (M3208+20n)
(a) This command is used to clear the servo error code storage register of an
axis for which the servo error detection signal has turn on (M2408+20n:
ON), and reset the servo error detection signal (M2408+20n).
Servo error reset command
(M3208+20n)
Servo error detection signal
(M2408+20n)
Servo error code storage
register
ON
OFF
OFF
ON
00
**
** : Error code
(b) If an error reset is executed during the temporary stop (M4003+10n) by the
temporary stop command (M4400+10n) at the automatic start or if an error
reset is executed during a block stop by M00/M01, the Motion program
operation state is reset.
The SVST instruction must be executed in the next strat. (Re-start is not
possible.)
Automatic start
(M4002+10n)
Temporary stop (M4003+10n)
Temporary stop command
(M4400+10n)
Block stop by M00/M01
OFF
ON
Start accept flag (M2001+n)
Servo error reset command
(M3208+20n)
Motion program (Axis
designation program) start
(c) When the error reset command is turned on at the automatic start
(M4002+10n: ON), the above reset processing is executed after the stop
processing by temporaty stop command (M4400+10n).
REMARK
Refer to APPENDIX 2 for details on the minor error code, major error code and
servo error code storage registers.
Summary of Contents for Q172CPU
Page 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Page 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Page 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Page 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Page 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...