[Setting range]
(1) Setting of axis to execute the speed change.
The axis to execute the speed change set as (S1) sets J + axis No. in a character
sequence " ".
(S1) usable range
Q173CPU(N)
1 to 32
Q172CPU(N)
1 to 8
The number of axes which can set are only 1 axis.
The axis No. set in the system setting (Refer to Section 6.1) is used as the axis
No. to start.
(2) Setting of the speed to change.
mm : -6000000 to 6000000 10
-2
[mm/min]
inch : -6000000 to 6000000 10
-3
[inch/min]
degree : -2147483648 to 2147483647 10
-3
[degree/min]
[Speed changing flag (System area)]
The complete status of the start accept flag is stored in the address of the start accept
flag in the shared CPU memory.
Shared CPU memory
address
( ) is decimal address
Description
206H(518)
207H(519)
The start accept flag is stored by the 1 to 32 axis, each bit.
(As for a bit's actually being set Q173CPU(N) : J1 to J32/
Q172CPU(N) : J1 to J8.)
OFF : Start accept usable
ON : Start accept disable
206H(518) address
207H(519) address
J2 J1
b1 b0
b15
J16
J32
J17