8 - 5
8 AUXILIARY AND APPLIED FUNCTIONS
(1) Watch data
(a) This data is used to perform the limit switch output function. This data is
comparison data to output the ON/OFF signal. The output device is
ON/OFF-controlled according to the ON region setting.
(b) As the watch data, motion control data or optional word device data can be
used.
1) Motion control data
Axis No. setting range
Item Unit
Data
type
Q173CPU(N) Q172CPU(N)
Machine value
Real machine value
Position command
Deviation counter value
PLS
32-bit
integer type
Motor current
(Command output voltage : ACF)
0.1% (0.01V)
16-bit
integer type
Motor speed
0.1r/min
Current value
Position command
32-bit
integer type
1 to 32
1 to 8
2) Word device data
Item
Device No. setting range
Data register
D0 to D8191
Link register
W0 to W1FFF
Motion register
#0 to #8191
3) When the optional device data is set, the following data type is set as the
data type to be compared.
Data type
Device No. setting range
16-bit integer type
32-bit integer type
64-bit floating-point type
Set the device No. as an even No..