78
Check of indoor fan motor
G
When OPERATION INDICATOR lamp flashes 3-time.
Indoor fan does not operate.
Check of remote controller and receiver P.C. board
H
Indoor unit operates by pressing the EMERGENCY OPERATION switch, but does not operate with the remote controller.
w
Check if the remote controller is exclusive for this air conditioner.
w
In case of replacing the receiver P.C. board, replace the indoor electronic control P.C. board with it because
they are unified.
●
Reinstall the unit
away from the lights.
●
Attach a filter on
receiving part.
Turn OFF the
power supply and
check the connector
CN 211 visually.
No(othes)
Yes
Yes
No
No
Yes
Yes
Ok
Disconnect lead wires from
CN 211 on indoor electronic
control P.C. board.
Measure resistance
between lead wire
1
and
3
and then
2
and
3
.
No
(not clear)
No
Yes(0 or
∞
)
Is LED display on
remote controller
visible?
Does the unit
operate with
remote
controller?
Is noise
heard from
the radio?
Are there any
fluorescent lights
of inverter or
radio start type
within 1 meter?
Is resistance
0
"
(short circuit) or
∞
(open circuit)?
Replace batteries and
then press RESET
button.
Refer to page 66.
Replace the indoor
electronic control
P.C. board with
power monitor,
receiver P.C. board.
Replace the
indoor fan motor.
Replace the
indoor
electronic
control P.C.
board.
CN211
3
2
1
Fan
motor
Indoor electronic
control P.C. board
Switch on the
remote controller.
Remove batteries, then set them back and
press the RESET button. Check if the unit
operates with the remote controller.
Tune a radio in to
AM and press
OPERATE/STOP
(ON/OFF) button
on remote
controller.
Replace the
remote
controller.
LD101T
1
2
3
4
5
1
2
3
4
5
Remote
controller
Indoor electronic
control P.C. board
Power monitor,
receiver P.C. board
Yes
OB245--3qxp 02.10.22 4:15 PM Page 78