102
OPERATING PROCEDURE
PHOTOS
7. Removing the compressor
(1) Remove the service panel, top panel and the cabinet.
(Refer to 1)
(2) Remove the soundproof felt.
(3) Remove the terminal cover on the compressor.
(4) Remove the electrical assembly. (Refer to 2)
(5) Recover gas from the refrigerant circuit.
(6) Disconnect the welded part of the discharge pipe.
(7) Disconnect the welded part of the suction pipe.
(8) Remove nuts fixing the compressor.
(9) Remove the compressor.
NOTE
●
Before using a burner, reclaim gas from the pipes until the
pressure gauge shows 0 kg/cm
2
(0MPa).
●
Use the burner under the condition that gas can be recovered
even when the inner pressure rises by heat.
6. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the propeller fan nut.
(3) Remove the propeller fan.
(4) Remove lead clamps and fan motor lead wires.
(5) Remove screws fixing the fan motor.
(6) Remove the outdoor fan motor.
Photo 5
Propeller fan
Propeller fan
nut
Set screws of the
outdoor fan motor
Lead clamps
Welded
parts
Compressor set nuts
OB245--4qxp 02.10.22 4:39 PM Page 102