76
Check of open phase
B
Check of transistor module
C
How to check inverter/ compressor
A
When OPERATION INDICATOR lamp flashes 5-time.
Outdoor unit does not operate.
Check the voltage
between terminals.
Check the
compressor.
Disconnect the connector
between compressor and
transistor module.
Check the resistance of transistor module.
See
D
“Check of compressor” on page 77.
No
See
B
“Check of open phase” on page 76.
See
C
'Check of transistor module' on page 76.
Is resistance
infinite?
Yes
Replace the outdoor
electronic control P.C.
board.
No
(0~several
"
)
Yes
Are voltages
balanced?
Replace the transistor
module.
●
Be sure to use the analog voltmeter for measurement.
●
With the connector between compressor and transistor module
disconnected, activate the inverter and measure the balance of
voltage between terminals.
<< Operation method>>
Start heating operation by pressing the EMERGENCY OPERATION switch
on the indoor unit. (test-run mode)
<<Measurement point>>
at 3 points
BLK-WHT
BLK-RED
WHT-RED
<<Judgment>>
Balanced································Normal
Unbalanced···························Abnomal (open phase)
Shutdown by overcurrent·······Abnormal (short)
NOTE 1. Measure AC voltage, at 3 points more than one minute after the
outdoor fan motor starts running.
2. The output voltage values in above table have tolerance within
J i
20%.
●
Disconnect the connector between compressor and transistor
module, and measure resistance between terminals on the
transistor module.
<<Measurement point>>
at 6 points
BLK-WHT, WHT-BLK
BLK-RED, RED-BLK
WHT-RED, RED-WHT
<<Judgment>>
Infinite [
"
]···········Normal
0~dozens of ······Abnormal (short)
COOL
HEAT
COOL
HEAT
79
58
85
58
190
155
190
155
Operational
frequency
[Hz]
Operation
mode
Model
MSZ-G09SV
Output
voltage
[V]
w
Measure AC voltage between
the lead wires at 3 points.
w
Measure resistance between
the lead wires at 3 points
ohmmeter indication
Normal
(infinite)
Abnormal
(0~dozens of
"
)
ACV
300
ACV
300
ACV
300
ACV
300
ACV
300
ACV
300
Normal
(Balanced)
Abnormal
(unbalanced)
BLK-WHT BLK-RED WHT-RED
BLK-WHT BLK-RED WHT-RED
Voltmeter indication
X1
"
X1
"
MSZ-G12SV
MSZ-G09SV -
MSZ-G12SV -
MUZ-G09SV -
MUZ-G12SV -
MSZ-G09SV -
MSZ-G12SV -
MUZ-G09SV -
MUZ-G12SV -
E2
E2
E2
E2
E1
E1
E1
E1
on page 76 ~ on page 83
A
Q