7
SPECIFICATION
3
Single phase
230V,50Hz
10
—
90
5.50
0.17
RC4V19-BA
WHT-BLK 292
BLK-RED 325
850
O
278
O
191
9
5
3
10
10
10
MUZ-G09SV -
E1
MUZ-G09SV -
E2
1,500
0.25
KHV-104FGK
900
U-V 2.14 U-W 2.14
V-W 2.14
RA6V18-AA
WHT-BLK 279
BLK-RED 198
710(+69)
o
540
o
255
28
45
600
1
0.75
270 (MS56)
33.2
13.4
7.9
Cooling
2.6 (1.3-3.1)
474/366
W
/252
W
1.2
4.54
940 (440 - 1,120)
2.77
36/29
W
/22
W
950/760
W
/570
W
4.12
Heating
3.6 (1.4-5.1)
504/402
W
/312
W
—
5.50
1,140 (430 - 1,300)
3.16
35/29
W
/22
W
1,000/830
W
/670
W
5.08
MSZ-G09SV -
E1
MSZ-G09SV -
E2
MSZ-G12SV -
E1
MSZ-G12SV -
E2
Single phase
230V,50Hz
10
—
90
7.40
0.19
RC4V19-BA
WHT-BLK 292
BLK-RED 325
850
O
278
O
191
10
5
3
10
10
10
MUZ-G12SV -
E1
MUZ-G12SV -
E2
1,560
0.34
SHV-130FEA
1,100
U-V 0.45 U-W 0.45
V-W 0.45
RA6V28-DA
WHT-BLK 201
BLK-RED 350
710(+69)
o
540
o
255
34
48
720
1
1.10
350 (MS56)
33.2
13.4
7.9
Cooling
3.5 (0.9-4.0)
588/444
W
/312
W
1.6
6.20
1,290 (290 - 1,390)
2.71
39/32
W
/25
W
1,020/810
W
/620
W
5.67
Heating
4.8 (0.9-6.7)
642/516
W
/366
W
—
7.40
1,540 (290 - 2,090)
3.12
39/34
W
/25
W
1,100/920
W
/700
W
6.87
Indoor model
Function
Power supply
Capacity
Air flow(High/Med.
W
/Low
W
)
Dehumidification
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20
:
)
Dimensions W
O
H
O
D
Weight
Air direction
Sound level(High/Med.
W
/Low
W
)
Fan speed(High/Med.
W
/Low
W
)
Fan speed regulator
Thermistor RT11(at25
:
)
Thermistor RT12(at25
:
)
Thermistor RT13(at25
:
)
Outdoor model
Air flow
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20
:
)
Model
Winding
resistance(at20
:
)
Dimensions W
O
H
O
D
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
Thermistor RT61(at0
:
)
Thermistor RT62(at100
:
)
Thermistor RT64(at70
:
)
kW
K
/h
r
/h
A
A
W
A(kW)
%
A
A
"
mm
kg
dB
rpm
k
"
k
"
k
"
K
/h
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k
"
k
"
k
"
Electrical
data
Fan
motor
Special
remarks
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance(C.O.P)
Capacity
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor
DB27
:
WB19
:
Outdoor DB35
:
WB 24
:
Heating : Indoor
DB 20
:
WB15
:
Outdoor DB 7
:
WB 6
:
Refrigerant piping length (one way): 5m
w
Reference value
OB245 --1qxp 02.10.22 4:08 PM Page 7