ADDITIONAL REFRIGERANT CHARGE (R22:g)
Outdoor unit
precharged
0
75
200
Refrigerant piping length (one way)
15m
10m
7m
Model
1,550
MSZ-G20SV -
E1
MUZ-G20SV -
E1
Outdoor unit
precharged
750
1100
14m
270
7m
60
60
6m
30
30
5m
0
0
11m
180
180
Model
Refrigerant piping length (one way)
Calculation : Xg=30g/m
o
(Refrigerant piping length(m) - 5)
8m
90
90
9m
120
120
10m
150
150
12m
210
210
13m
240
15m
300
MSZ-G09SV -
E1
MUZ-G09SV -
E1
MSZ-G09SV -
E2
MUZ-G09SV -
E2
MSZ-G12SV -
E1
MUZ-G12SV -
E1
MSZ-G12SV -
E2
MUZ-G12SV -
E2
Calculation : Xg=25g/m
o
(Refrigerant piping length(m) - 7)
Refrigerant Piping
Max. length
A
w
Height difference should be within
8m(MSZ-G09SV)/ 10m(MSZ-G12/ G20SV)
regardless of which unit,
indoor or outdoor position is high.
w
Max. Height
difference 8m
(MSZ-G09SV)
Indoor
unit
Outdoor unit
w
Max. Height
difference 10m
(MSZ-G12/ G20SV)
MAX. HEIGHT DIFFERENCE
OB245 --1qxp 02.10.22 4:08 PM Page 23