7 - 1
7. TROUBLESHOOTING
7. TROUBLESHOOTING
7.1 Converter unit
7.1.1 Alarms and warning list
When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to Section 6.2.2 or 6.2.3 and take the appropriate action.
Switch power off, then on to deactivate the alarm. The alarms marked " " in the Alarm Deactivation
column of the table can be deactivated by pressing the "RES" key of the servo amplifier side parameter
unit or switching on the reset signal (RES).
Indication
Function Name
Alarm Deactivation
A.10
Under voltage
A.12
Memory alarm 1
A.13
Clock alarm
A.15
Memory alarm 2
A.30
Regenerative alarm
A.33
Over voltage
A.37
Parameter alarm
A.45
Main circuit device
overheat
A.50
Over load 1
A.51
Over load 2
Al
ar
m
8888
Watchdog
A.E0
Excessive regenerative
load warning
A.E1
Over load warning
War
ning
A.E9
Undervoltage
warning
7.1.2 Remedies for alarms
CAUTION
When any alarm has occurred, eliminate its cause, ensure safety, then reset the
alarm, and restart operation. Otherwise, injury may occur.
POINT
When any of the following alarms has occurred, always remove its cause
and allow about 30 minutes for cooling before resuming operation. If
operation is resumed by switching control circuit power off, then on to
reset the alarm, the converter unit and regenerative brake option may
become faulty.
Regenerative alarm (A.30)
Overload 1 (A.50)
Overload 2 (A.51)
The alarms can be deactivated by switching power off, then on, by
pressing the "RES" key of the parameter unit or by turning on the reset
signal (RES).
When an alarm occurs, the trouble (ALM) signal switches off and the display section shows the alarm
number.
Remove the cause of the alarm in accordance with this section.
Downloaded from
Summary of Contents for MELSERVO MR-HP30KA
Page 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Page 15: ...4 MEMO Downloaded from ManualsNet com search engine ...
Page 63: ...5 6 5 PARAMETER MEMO Downloaded from ManualsNet com search engine ...
Page 71: ...7 6 7 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Page 79: ...8 8 8 OUTLINE DIMENSIONAL DRAWINGS MEMO Downloaded from ManualsNet com search engine ...