2 - 2
2. INSTALLATION
2.2 Installation direction and clearances
CAUTION
Install the equipment in the specified direction. Not doing so can cause a failure.
Leave the specified clearances between the converter unit/servo amplifier and the
control box inside walls or other equipment. Not doing so can cause a failure.
(1) Installation of one servo amplifier
Servo Amplifier
50mm
(1.969in)
or more
100mm
(3.937in)
or more
12
0
m
m
(4.724i
n
)
o
r more
Front view
Top
Bottom
Converter unit
50mm
(1.969in)
or more
10
0
m
m
(3.937i
n
)
o
r more
Side view
(2) Mounting dimensional diagram
[Unit: mm]
([Unit: in])
Dimensions
Servo Amplifier
W1
W2
MR-J2S-30KA4/B4
MR-H30KAN4/BN4
380
(14.96)
290
(11.42)
MR-J2S-30KA/B 37KA/B
MR-J2S-37KA4/B4 45KA4/B4 55KA/B4
MR-H30KAN/BN 37KAN/BN
MR-H37KAN4/BN4 45KAN/BN4
55KAN4/BN4
450
(17.717)
360
(14.173)
Converter
unit
Servo amplifier
Exclusive
connection conductor
8-M10 screw
110
(4.33)
200
(4.66)
20
W2
W1
480
(18
.9)
500
(19
.69)
10(
0.
39
)
10
(0
.3
9)
45
(1.77)
45
(1.77)
45
(1.77)
45
(1.77)
(0.47)
(3) Others
When using heat generating equipment such as the regenerative brake option, install them with full
consideration of heat generation so that the Converter unit and servo amplifier is not affected.
Install the Converter unit and servo amplifier on a perpendicular wall in the correct vertical direction.
Downloaded from
Summary of Contents for MELSERVO MR-HP30KA
Page 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Page 15: ...4 MEMO Downloaded from ManualsNet com search engine ...
Page 63: ...5 6 5 PARAMETER MEMO Downloaded from ManualsNet com search engine ...
Page 71: ...7 6 7 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Page 79: ...8 8 8 OUTLINE DIMENSIONAL DRAWINGS MEMO Downloaded from ManualsNet com search engine ...