1 - 9
1. FUNCTIONS AND STRUCTURE
1.7 Parts identification
The rating plate is on the right side face when viewed from the front.
1.7.1 Converter unit (MR-HP-30KA/MR-HP55KA4)
Refer To
TE2-1, TE2-2 (PN terminals)
Connect to the servo amplifier using the connection
conductors supplied to the servo amplifier.
Display
The four-digit, seven-segment LED shows the servo
status and alarm number.
Section
7.1
Operation section
Used to perform status display, diagnostic, alarm and
parameter point table operations.
MOVE
UP
DOWN
SET
Used to set data.
Used to change the
display data in each
mode.
Used to change the
mode.
Charge lamp
Lit to indicate that the main circuit is charged. While
this lamp is lit, do not reconnect the cables.
CN1
Outputs an alarm signal.
CN3
For maker adjustment. Leave this open.
CN6
For maker adjustment. Leave this open.
CN5
Connect to CN5A of the servo amplifier.
(Ground terminal)
TE1-2
Supply main circuit power.
Section
3.3.2
TE1-1
Connect the regenerative brake option or power factor
improving DC reactor.
TE3
Supply control circuit power.
Section 3.1.1
Name/Application
Section 3.3.2
Chapter 4
Section 3.3.2
Section 3.3.2
Section 3.3.2
TE2-1
TE2-2
TE1-1
TE1-2
TE3
Downloaded from
Summary of Contents for MELSERVO MR-HP30KA
Page 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Page 15: ...4 MEMO Downloaded from ManualsNet com search engine ...
Page 63: ...5 6 5 PARAMETER MEMO Downloaded from ManualsNet com search engine ...
Page 71: ...7 6 7 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Page 79: ...8 8 8 OUTLINE DIMENSIONAL DRAWINGS MEMO Downloaded from ManualsNet com search engine ...