4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT
4.4 Alarm mode
The current alarm, parameter error and point table error are displayed.
The lower 2 digits on the display indicate the alarm number that has occurred or the parameter number
in error.
Display example are shown below.
Name
Display
Description
Indicates on occurrence of an alarm.
Current alarm
Indicates that overvoltage (A.33) occurred.
Flickers at alarm occurrence.
Indicates that the last alarm is overload (A.50).
Indicates that the second alarm in the past is overvoltage
(A.33).
Indicates that the third alarm in the past is undervoltage
(A.10).
Indicates that the fourth alarm in the past is undervoltage
(A.10).
Indicates that the fifth alarm in the past is undervoltage
(A.10).
Indicates that the sixth alarm in the past is overload
(A.50).
Indicates that there is no seventh alarm in the past.
Indicates that there is no eighth alarm in the past.
Indicates that there is no ninth alarm in the past.
Alarm history
Indicates that there is no tenth alarm in the past.
Indicates no occurrence of parameter error (A37).
Parameter error
Indicates that the data of parameter No.1 is faulty.
Functions at occurrence of an alarm
(1) Any mode screen displays the current alarm.
(2) The other screen is visible during occurrence of an alarm. At this time, the decimal point in the fourth
digit flickers.
(3) To clear any alarm, switch power off, then on or press the "SET" button on the current alarm screen.
Note that this should be done after removing the case of the alarm.
Downloaded from
Summary of Contents for MELSERVO MR-HP30KA
Page 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Page 15: ...4 MEMO Downloaded from ManualsNet com search engine ...
Page 63: ...5 6 5 PARAMETER MEMO Downloaded from ManualsNet com search engine ...
Page 71: ...7 6 7 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Page 79: ...8 8 8 OUTLINE DIMENSIONAL DRAWINGS MEMO Downloaded from ManualsNet com search engine ...