4 - 2
4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT
4.2 Status display mode
The servo status during operation is shown on the 4-digit, 7-segment LED display. Press the "UP" or
"DOWN" button to change display data as desired.
When the required data is selected, the corresponding symbol is displayed. Press the "SET" button to
display that data.
The converter unit display section can show four items of data such as the effective load factor.
4.2.1 Display examples
The following table shows the display examples.
Item
Status
Display
Bus voltage
225[V]
Effective load factor
67[%]
Peak load factor
95[%]
Regenerative load factor
90[%]
4.2.2 Status display list
The following table lists the servo statuses that may be displayed.
Status Display
Symbol
Unit
Description
Indication Range
Bus voltage
d
V
The converter unit voltage is displayed.
0 to 500
Effective load factor
J
%
Continuous effective load torque is displayed.
(Note)
The effective value in the past 15 seconds is displayed
relative to the rated current of 100%.
0 to 300
Peak load factor
b
%
The peak output is displayed.
(Note)
The peak value in the past 15 seconds is displayed
relative to the rated torque of 100%.
0 to 300
Regenerative load
factor
L
%
The percentage of regenerative power to the
permissible regenerative value is displayed.
0 to 300
Note. Output speed
torque
Downloaded from
Summary of Contents for MELSERVO MR-HP30KA
Page 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Page 15: ...4 MEMO Downloaded from ManualsNet com search engine ...
Page 63: ...5 6 5 PARAMETER MEMO Downloaded from ManualsNet com search engine ...
Page 71: ...7 6 7 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Page 79: ...8 8 8 OUTLINE DIMENSIONAL DRAWINGS MEMO Downloaded from ManualsNet com search engine ...