5 - 3
5. PARAMETER
(3) MR-J2S- B
No.
Symbol
Name and function
Initial value
Unit
2
*REG
Regenerative brake resistor
0
Regenerative brake option selection
Always set "0".
Refer to the MR-J2S- B Servo Amplifier Instruction Manual.
0 0
0000
(4) MR-J2S- B4
No.
Symbol
Name and function
Initial value
Unit
2
*REG
Regenerative brake resistor
0
Regenerative brake option selection
Always set "0".
Refer to the MR-J2S- B Servo Amplifier Instruction Manual.
0 0
0000
22
MOD
Analog monitor output
Setting
0
Servo motor speed ( 8V/max. speed)
1
Torque ( 8V/max. torque)
2
Motor speed ( 8V/max. speed)
3
Torque ( 8V/max. torque)
4
Current command ( 8V/max. current command)
5
Command speed ( 8/max. speed)
6
Droop pulses ( 10V/128 pulses)
7
Droop pulses ( 10V/2048 pulses)
8
Droop pulses ( 10V/8192 pulses)
9
Droop pulses ( 10V/32768 pulses)
A
Droop pulses ( 10V/131072 pulses)
0
0
B
Bus voltage ( 8V/800V)
Analog monitor 1 (MO1) Analog monitor 2 (MO2)
0001