950
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
Appendix A-1-2 Cautions on writing during RUN
"In the FX
3G
, FX
3U
and FX
3UC
PLCs, writing is enabled during RUN (program changes during RUN mode)
using the following programming tools."
→
For the operating procedure of and cautions on writing during RUN,
refer to the respective programming tool manual.
Programming tools which support writing during RUN
Programming tool
PLC
Version
Remarks
GX Developer
FX
3G
Ver.2.00A or later
Writing in the instruction and device ranges during RUN is
supported in FX
2N
PLCs Ver.1.00 or later.
Ver.5.00A or later
Writing in the instruction and device ranges during RUN is
supported in FX
1N
PLCs Ver.1.00 or later.
Ver.8.72A or later
Writing in the instruction and device ranges during RUN is
supported in FX
3G
PLCs Ver.1.00 or later.
Ver.8.78G or later
Writing in the instruction and device ranges during RUN is
supported in FX
3G
PLCs Ver.1.10 or later.
FX
3U
/FX
3UC
Ver.7.00A or later
Writing in the instruction and device ranges during RUN is
supported in FX
2N
PLCs Ver.3.00 or later.
Ver.8.13P or later
Writing in the instruction and device ranges during RUN is
supported in FX
3UC
PLCs Ver.1.00 or later.
Ver.8.18U or later
Writing in the instruction and device ranges during RUN is
supported in FX
3UC
PLCs Ver.1.30 or later.
Ver.8.23Z or later
Writing in the instruction and device ranges during RUN is
supported in FX
3U
and FX
3UC
PLCs Ver.2.20 or later.
Ver. 8.29F or later
Writing in the instruction and device ranges during RUN is
supported in FX
3U
and FX
3UC
PLCs Ver.2.30 or later
Ver.8.82L or later
Writing in the instruction and device ranges during RUN is
supported in FX
3U
and
FX
3UC
PLCs Ver.2.61 or later.
FX-PCS/WIN
FX
3G
Ver.1.00 or later
Writing in the instruction and device ranges during RUN is
supported in FX
2
PLCs Ver.3.30 or later.
FX
3U
/FX
3UC
Ver.2.00 or later
Writing in the instruction and device ranges during RUN is
supported in FX
2N
PLCs Ver.1.00 or later.
Ver.4.00A or later
Writing in the instruction and device ranges during RUN is
supported in FX
1N
PLCs Ver.1.00 or later.
Ver.4.20 or later
Writing in the instruction and device ranges during RUN is
supported in FX
2N
PLCs Ver.3.00 or later.
FX-PCS/WIN-E
FX
3G
Ver.3.00 or later
Writing in the instruction and device ranges during RUN is
supported in FX
1N
PLCs Ver.1.00 or later.
FX
3U
/FX
3UC
Ver.1.00 or later
Writing in the instruction and device ranges during RUN is
supported in FX
2
PLCs Ver.3.30 or later.
Ver.1.00 or later
Writing in the instruction and device ranges during RUN is
supported in FX
2N
PLCs Ver.1.00 or later.
Ver.3.10 or later
Writing in the instruction and device ranges during RUN is
supported in FX
2N
PLCs Ver.3.00 or later.