15 External FX I/O Device – FNC 70 to FNC 79
15.5 FNC 74 – SEGL / Seven Segment With Latch
11
FNC3
0-F
NC3
9
R
otati
on and
Shif
t
12
FNC4
0-F
NC4
9
D
ata
O
per
ati
on
13
FN
C
50-FN
C
59
H
igh Speed
Pr
ocess
ing
14
FM
C
60-
FN
C
69
H
andy
In
st
ru
ct
ion
15
FNC7
0-F
N
C7
9
Ex
ter
nal
FX
I/O
D
evice
16
FN
C
80-FN
C
89
Ext
ernal FX
De
vic
e
17
FN
C
100-
FN
C
109
Da
ta
Transf
er 2
18
FN
C
110-
FN
C
139
Fl
oati
ng Poi
nt
19
FN
C
140
-F
N
C
14
9
Da
ta
O
per
ati
on 2
20
FN
C
150-
FN
C
159
Posit
ioning
C
ontr
ol
3) Example of connecting one seven-segment display unit
The figure below shows an example of the FX
3U
series main unit (sink output).
For wiring details, refer to the following manuals.
→
FX
3G
Hardware Edition
→
FX
3U
Hardware Edition
→
FX
3UC
Hardware Edition
When using two sets of 4 digits (n = K4 to K7)
→
For selection of "n", refer to Subsection 15.5.2.
1) Data and strobe signal
a) 1st set of 4 digits
A 4-digit numeric value stored in
is converted from binary into BCD, and its each digit is output
in turn from
to
+3 in the time division method.
The strobe signal is output in turn from
+4 to
+7 in the time division method also to latch
the first set of 4-digit seven-segment display unit.
b) 2nd set of 4 digits
A 4-digit numeric value stored in
+1 is converted from binary into BCD, and its each digit is
output in turn from
+10 to
+13 in the time division method.
The strobe signal is output in turn from
+4 to
+7 in the time division method also to latch
the second set of 4-digit seven-segment display unit. (The strobe signal outputs
+4 to
+7
are shared by the 1st and 2nd sets.)
2) For
and
+1, binary data in the range from 0 to 9999 is valid.
3) Example of connecting two seven-segment display units
The figure below shows an example of the FX
3U
series main unit (sink output).
For wiring details, refer to the following manuals.
→
FX
3G
Hardware Edition
→
FX
3U
Hardware Edition
→
FX
3UC
Hardware Edition
10
0
4
2
8
1
1
2
4
8
1st set
V+
10
1
10
2
10
3
10
3
10
2
10
1
10
0
COM
+1
+2
+3
+4
+6
+7
+5
PLC (transistor output type)
D
D
D
D
D
D
D
D
S
D
D
D
D
S
D
D
D
D
D
D
S
S
10
0
4
2
8
1
1
2
4
8
1st set
V+
10
1
10
2
10
3
10
3
10
2
10
1
10
0
COM
+1
PLC
(transistor output type)
+2
+3
+4
+6
+7
+5
D
D
D
D
D
D
D
D
2nd set
V+
1
2
4
8
4
2
8
1
10
3
10
2
10
1
10
0
+10
+11
+12
+13
D
D
D
D
COM