782
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
33 Extension File Register Control – FNC290 to FNC299
33.5 FNC294 – RWER / Rewrite to ER
Program example
In the program example shown below, the contents of extension registers R10 to R19 (sector 0) used for
setting data are reflected on extension file registers (ER) when X000 turns ON.
Program
Operation
M0
MOV
D8000
D200
X000
K47
D8000
PLS
M0
END
FNC294
RWER
R10
K10
ADD
D8000
MOV
D200
D8000
FNC 07
WDT
FNC 07
WDT
R0
K100
R1
K105
R10
K200
R11
K215
R12
K400
R19
K350
R99
K1000
R100
HFFFF
HFFFF
R2047
ER0
K100
ER1
K105
ER10
K200
ER11
K215
ER12
K400
ER19
K350
ER99
K1000
ER100
HFFFF
HFFFF
ER2047
Write
(when X000
turns ON)
Setting data
Device number Current
value
Extension registers (R)
Setting backup data
Extension file registers
(ER)
Device number Current
value
S
e
tting data (A
)
Changed data
U
nused
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.