Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
14 Handy Instruction – FNC 60 to FNC 69
14.1 FNC 60 – IST / Initial State
11
FNC3
0-F
NC3
9
R
otati
on and
Shif
t
12
FNC4
0-F
NC4
9
D
ata
O
per
ati
on
13
FN
C
50-FN
C
59
H
igh Speed
Pr
ocess
ing
14
FM
C
60-
FN
C
69
H
andy
In
st
ru
ct
ion
15
FNC7
0-F
N
C7
9
Ex
ter
nal
FX
I/O
D
evice
16
FN
C
80-FN
C
89
Ext
ernal FX
De
vic
e
17
FN
C
100-
FN
C
109
Da
ta
Transf
er 2
18
FN
C
110-
FN
C
139
Fl
oati
ng Poi
nt
19
FN
C
140
-F
N
C
14
9
Da
ta
O
per
ati
on 2
20
FN
C
150-
FN
C
159
Posit
ioning
C
ontr
ol
2. Transfer mechanism
The upper left position is regarded as the zero point. The machine transfers a workpiece from the left to the
right in the order "moving down
→
clamping
→
moving up
→
rightward travel
→
moving down
→
unclamping
→
moving up
→
leftward travel."
Double-solenoid type solenoid valves (with two inputs for driving and non-driving) are adopted for moving
down, moving up, leftward travel and rightward travel. Single type solenoid valves (which operate only while
the power is ON) are adopted for clamping.
Zero point
Left limit X004
Start
X026
Upper limit X002
Clamping
Lower
limit
X001
(1) Moving
down
Y000
(3) Moving up
Y002
(2) Clamping
Y001 ON
Upper
limit
X002
Unclamping
Lower
limit
X001
(1) Moving down
Y000
(7) Moving up
Y002
(6) Unclamping
Y001 OFF
Right limit
X003
(4) Rightward Y003
(8) Leftward Y004
What is the zero point condition?
Upper limit X002 is ON, left limit
X004 is ON and unclamping Y001
is OFF.