Chapter 4 Setup
4-3
4-2 Setting the initial parameters
The servo parameters must be set to start up the servo drive system.
The servo parameters are input from the CNC. The input method will differ according to the CNC, so
refer to the Instruction Manual provided with each CNC.
4-2-1 Servo specification parameters
The servo specification parameters are determined according to the machine specifications and servo
system specifications.
No.
Abbrev.
Parameter name
Explanation
SV017 SPEC Servo
specification
selection
This is a HEX setting parameter. Set this as follows according to the
servo specifications.
Set all bits other than those above to 0.
SV025 MTYP Motor/Detector type
Set the motor type.
Refer to the standard parameter list for each motor for the settings.
SV036 PTYP Regenerative resistor type This is a HEX setting parameter.
SV027 SSF1 Servo function selection 1 Set 4000 as a standard.
SV033 SSF2 Servo function selection 2 Set 0000 as a standard.
SV001
PC1
Motor side gear ratio
SV002
PC2
Machine side gear ratio
Set the motor side gear ratio in PC1 and the machine side gear ratio in
PC2.
When using a rotary axis, set the total deceleration (acceleration) ratio.
SV018
PIT
Ball screw pitch
Set the ball screw pitch with an mm unit. Set 360 for a rotary axis.
SV019 RNG1 Position
detector
resolution
SV020 RNG2 Speed detector resolution
Set the motor detector resolution with a kp/rev unit for both settings.
Refer to the standard parameters for each motor for the settings.
SV003 PGN1 Position loop gain
Set 33 as a standard.
F
E
D
C
B
A
9
8
7
6
5 4 3 2 1
0
abs
vdir
mc
dmk
bit
Meaning when "0" is set.
Meaning when "1" is set.
0
dmk
Deceleration control stop
(SVJ2 standard)
Dynamic brake stop
3
mc Contactor control output invalid
Contactor control output valid
5
vdir
HA053N to HA33N motor
detector standard installation
position (A, C)
HA053N to HA33N motor
detector 90
°
installation position
(B, D)
7
abs Incremental control
Absolute position control
F
E
D
C
B
A
9
8
7
6 5 4 3 2 1
0
amp rtyp emgx
bit
Descriptions
0~3 Always set to "0" (0000).
Set the external emergency stop function. (Setting is prohibited for
values with no description.)
Setting
value
Details
0
External emergency stop invalid
4
External emergency stop valid
4~7
Set the regenerative resistor type.
Setting
value
Details
0
Amplifier standard built-in resistor (SVJ2-01 has no built-in
resistor.)
1 Setting
prohibited
2 MR-RB032
3
MR-RB12 or GZG200W39OHMK
4
MR-RB32 or GZG200W120OHMK:
3 units connected in parallel
5
MR-RB30 or GZG200W39OHMK:
3 units connected in parallel
6
MR-RB50 or GZG300W39OHMK:
3 units connected in parallel
7 ~ F
Setting prohibited
8~B
C~ F Always set to "1" (0001).
Summary of Contents for MELDAS MDS-B-SVJ2 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 46: ......
Page 92: ......
Page 108: ......
Page 152: ......
Page 186: ......
Page 194: ......
Page 218: ......
Page 260: ......
Page 282: ......
Page 283: ...12 1 Chapter 12 Inspections 12 1 Inspections 12 2 12 2 Life parts 12 2 ...
Page 294: ......
Page 297: ......