![Mitsubishi Electric MELDAS MDS-B-SVJ2 Series Specifications And Instruction Manual Download Page 55](http://html.mh-extra.com/html/mitsubishi-electric/meldas-mds-b-svj2-series/meldas-mds-b-svj2-series_specifications-and-instruction-manual_239059055.webp)
Chapter 2 Wiring and Connection
2-9
2-3 NC and servo amplifier connection
The NC bus cables are connected from the NC to each servo amplifier so that they run in a straight
line from the NC to the terminator connector (battery unit). MDS-C1-V1/V2 Series servo amplifiers and
spindle amplifiers can be connected in combination, and up to 7 axes can be connected per system.
(Note that the number of connected axes is limited by the NC. The following drawing shows an
example with three axes connected.)
< Connection >
CN1A : CN1B connector of NC side amplifier or NC output
CN1B : CN1A connector of terminator connector side amplifier or terminator connector (battery
unit)
CAUTION
Arrange the NC and servo amplifiers so that the NC bus cable length from the
NC to the terminator connector (battery unit) is 30m or less.
POINT
Axis Nos. are determined by the rotary switch for setting the axis No. (Refer to
section "4-1-1 Setting the rotary switches".) The axis No. has no relation to the
order for connecting to the NC.
CN1B
CN1A
CN1B
CN1A
CN1B
CN1A
SH21 cable
Connect to the
battery unit with a
terminator connector
or SH21 cable.
MDS-B-SVJ2
3rd axis (final axis)
MDS-B-SVJ2
2nd axis
MDS-B-SVJ2
1st axis
Connected to the NC
Refer to the
instruction manual
of each NC for
details.
Max. length of 30m from the NC to the terminator connector.
Summary of Contents for MELDAS MDS-B-SVJ2 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 46: ......
Page 92: ......
Page 108: ......
Page 152: ......
Page 186: ......
Page 194: ......
Page 218: ......
Page 260: ......
Page 282: ......
Page 283: ...12 1 Chapter 12 Inspections 12 1 Inspections 12 2 12 2 Life parts 12 2 ...
Page 294: ......
Page 297: ......