Chapter 5 Adjustment
5-40
No. Abbrev. Parameter
name
Explanation
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
cl2n
clG1
bit
Meaning when “0” is set
Meaning when “1” is set
0
1
2
3
4
SV035 SSF4
Servo function
selection 4
5
6
7
8
9
10
11
12
Collision detection method 1
Set the collision detection level during cutting feed (G1).
13 clG1 The G1 collision detection level=SV060*clG1.
14
When clG1=0, the collision detection method 1 during cutting feed
won’t function.
15 cl2n
Collision detection method 2
valid
Collision detection method 2
invalid
(Note) Set to “0” for bits with no particular description.