Chapter 8 Troubleshooting
8-12
• Deceleration method
Deceleration control : The motor will be decelerated and controlled with the time constant set in the parameter
(EMGt).
If dynamic brake stop is selected with the parameter (SPEC), the motor will stop with the
dynamic brakes.
Dynamic : The motor will stop with the dynamic brakes, even if a deceleration stop is set.
• Reset method
∗
: The unit will be automatically reset when the state in which the warning occurred is canceled.
NR
: Reset with the CNC reset button. Resetting is also possible with the PR, AR resetting conditions.
PR
: Reset by turning the CNC power ON again. Resetting is also possible with the AR resetting
conditions.
Resetting while the control axis is removed is possible with the CNC unit reset button. (Note that
alarm 32, 37 and warning 93 are excluded.)
AR
: Reset by turning the servo amplifier power ON again.