Chapter 5 Adjustment
5-41
No. Abbrev. Parameter
name
Explanation
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
amp
rtyp
emgx
bit
Explanation
0
Always set to “0(0000)”.
1
2
3
4
Set the external emergency stop function. (Setting is prohibited for
values with no description.)
5 emgx
Setting
Explanation
6
0
External emergency stop invalid
7
4
External emergency stop valid
SV036 PTYP*
Regenerative
resistor type
8
Set the regenerative resistor type.
9
Setting
Explanation
10
rtyp
0
Drive unit standard built-in resistor (SVJ2-01 doesn’t have a
built-in resistor)
11
1 Setting
prohibited
2 MR-RB032
3
MR-RB12 or GZG200W390HMK
4
MR-RB32 or GZG200W1200HMK: 3 units connected in parallel
5
MR-RB30 or GZG200W390HMK: 3 units connected in parallel
6
MR-RB50 or GZG300W390HMK: 3 units connected in parallel
7 to F
Setting prohibited
12
Always set to “0(0000)”.
13
14
amp
15
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated when the NC power is turned ON again.