![Mitsubishi Electric LD77MH User Manual Download Page 81](http://html.mh-extra.com/html/mitsubishi-electric/ld77mh/ld77mh_user-manual_239045081.webp)
2 - 33
Chapter 2 Input Axis Module
2.2.5 Synchronous encoder axis monitor data
Monitor item
Storage details
Monitor value
Buffer memory
address
[Md.320]
Synchronous encoder
axis current value
• The current value for the synchronous
encoder axis is stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Synchronous encoder axis position units
(Note-1)
]
35200+20j
35201+20j
[Md.321]
Synchronous encoder
axis current value per
cycle
• The current value per cycle for a
synchronous encoder axis is stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
0 to (Synchronous encoder axis length per cycle-1)
[Synchronous encoder axis position units
(Note-1)
]
35202+20j
35203+20j
[Md.322]
Synchronous encoder
axis speed
• The speed for a synchronous encoder
axis is stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Synchronous encoder axis speed units
(Note-2)
]
35204+20j
35205+20j
[Md.323]
Synchronous encoder
axis phase
compensation amount
• The phase compensation amount is
stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Synchronous encoder axis position units
(Note-1)
]
35206+20j
35207+20j
[Md.324]
Synchronous encoder
axis rotation direction
restriction amount
• While the rotation direction is
restricted, the accumulation for the
input travel value in the opposite
direction of the enabled direction is
stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Synchronous encoder axis position units
(Note-1)
]
35208+20j
35209+20j
[Md.325]
Synchronous encoder
axis status
• The status for a synchronous encoder
axis is monitored.
Refresh cycle: Operation cycle
Monitoring is carried out in hexadecimal.
b0
b1
b2
b3
b4
b5 Warning detection flag
Error detection flag
0: OFF
1: ON
Not used
Buffer memory
b15
b12
b8
b4
b0
Setting valid flag
Connecting valid flag
Counter enable flag
Current value setting request flag
Stored items
Meaning
35210+20j
[Md.326]
Synchronous encoder
axis error No.
• The error code for the synchronous
encoder axis is stored.
Refresh cycle: Operation cycle
Monitoring is carried out in hexadecimal.
(Refer to Section 6.2.1 "List of input axis errors")
35211+20j
[Md.327]
Synchronous encoder
axis warning No.
• The warning code for the synchronous
encoder axis is stored.
Refresh cycle: Operation cycle
Monitoring is carried out in hexadecimal.
(Refer to Section 6.2.2 "List of input axis warnings")
35212+20j
j: Synchronous encoder axis No.-1
(Note-1): Synchronous encoder axis position units (Refer to Section 2.2.1)
(Note-2): Synchronous encoder axis speed units (Refer to Section 2.2.1)
Summary of Contents for LD77MH
Page 2: ......
Page 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Page 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Page 104: ...3 20 Chapter 3 Cam Function MEMO ...
Page 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Page 234: ...Appendix 18 Appendices MEMO ...
Page 237: ......