[Cd.607] Cam data value
Set/load the cam data operation points according to one of the following formats.
(1) Stroke ratio data format
Buffer memory
address
Item Setting
value
45008
45009
Stroke ratio at first point
-2147483648 to 2147483647 [ 10
-7
%]
(-214.7483648 to 214.7483647 [%])
45010
45011
Stroke ratio at second point
to to
53198
53199
Stroke ratio at 4096th point.
(2) Coordinate data format
Buffer memory
address
Item Setting
value
45008
45009
At first point
Input value
0 to 2147483647
[Cam axis cycle unit]
45010
45011
Output value
-2147483648 to 2147483647
[Output axis position unit]
45012
45013
At second point
Input value
0 to 2147483647
[Cam axis cycle unit]
45014
45015
Output value
-2147483648 to 2147483647
[Output axis position unit]
to to
to
53196
53197
At 2048th point
Input value
0 to 2147483647
[Cam axis cycle unit]
53198
53199
Output value
-2147483648 to 2147483647
[Output axis position unit]
Not set
Set
0
0
2
[Cd.601] to [Cd.607] Cam data
[Cd.600] Cam data operation request
Summary of Contents for LD77MH
Page 2: ......
Page 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Page 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Page 104: ...3 20 Chapter 3 Cam Function MEMO ...
Page 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Page 234: ...Appendix 18 Appendices MEMO ...
Page 237: ......