Item
Buffer memory
address
Reference
section
[Pr.434]
Speed change ge
ar Speed change gear
36460+200n
Section 4.4.2
[Pr.435]
Speed change gear smoothing time constant
36461+200n
[Pr.436]
Speed change ratio: Numerator
36462+200n
36463+200n
[Pr.437]
Speed change ratio: Denominator
36464+200n
36465+200n
[Pr.438]
O
utput axis
Cam axis cycle unit setting
36470+200n
Section 4.5.2
[Pr.439]
Cam axis length per cycle
36472+200n
36473+200n
[Pr.440]
Cam No.
36474+200n
[Pr.441]
Cam stroke amount
36476+200n
36477+200n
[Pr.444]
Cam axis phase compensation advance time
36482+200n
36483+200n
[Pr.445]
Cam axis phase compensation time constant
36484+200n
[Pr.446]
Synchronous control deceleration time
36485+200n
[Pr.447]
Output axis smoothing time constant
36486+200n
[Pr.460]
Synchronous
control in
itial po
si
tion
Setting method of current value per cycle after
main shaft gear
36500+200n
Section 5.2
[Pr.461]
Setting method of current value per cycle after
auxiliary shaft gear
36501+200n
[Pr.462]
Cam axis position restoration object
36502+200n
[Pr.463]
Setting method of cam reference position
36503+200n
[Pr.464]
Setting method of cam axis current value per
cycle
36504+200n
[Pr.465]
Current value per cycle after main shaft gear
(Initial setting)
36506+200n
36507+200n
[Pr.466]
Current value per cycle after auxiliary shaft
gear (Initial setting)
36508+200n
36509+200n
[Pr.467]
Cam reference position (Initial setting)
36510+200n
36511+200n
[Pr.468]
Cam axis current value per cycle (Initial setting)
36512+200n
36513+200n
n: Axis No.-1
Summary of Contents for LD77MH
Page 2: ......
Page 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Page 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Page 104: ...3 20 Chapter 3 Cam Function MEMO ...
Page 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Page 234: ...Appendix 18 Appendices MEMO ...
Page 237: ......