2 - 8
Chapter 2 Input Axis Module
2.1.3 Servo input axis monitor data
Monitor item
Storage details
Monitor value
Buffer memory
address
[Md.300]
Servo input axis current
value
• The current value for the servo input axis is
stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Servo input axis position units
(Note-1)
]
33120+10n
33121+10n
[Md.301]
Servo input axis speed
• The speed for the servo input axis is stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Servo input axis speed units
(Note-2)
]
33122+10n
33123+10n
[Md.302]
Servo input axis phase
compensation amount
• The current phase compensation amount is
stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Servo input axis position units
(Note-1)
]
33124+10n
33125+10n
[Md.303]
Servo input axis rotation
direction restriction
amount
• While the rotation direction is restricted, the
accumulation for the input travel value in the
opposite direction of the enabled direction is
stored.
Refresh cycle: Operation cycle
Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Servo input axis position units
(Note-1)
]
33126+10n
33127+10n
n: Axis No.-1
(Note-1): Servo input axis position units (Refer to Section 2.1.1)
(Note-2): Servo input axis speed units (Refer to Section 2.1.1)
[Md.300] Servo input axis current value
The current value for the servo input axis is stored in servo input axis position units (Refer
to Section 2.1.1) as follows.
The current value for the servo input axis is the value after processing the smoothing, the
phase compensation and the rotation direction restriction.
Setting value of "[Pr.300]
Servo input axis type"
Storage details
1: Feed current value
2: Real current value
• The accumulative current value started with "[Md.20] Feed current
value"/"[Md.101] Real current value" for the connection to the servo amplifier is
stored. It is also stored in the range from -21474.83648 to 21474.83647 [degree]
for degree units.
• When the "[Md.20] Feed current value"/"[Md.101] Real current value" is changed
by an OPR or a current value change, the value is changed to the new current
value.
3: Servo command value
4: Feedback value
• When of the absolute position detection system setting is invalid, the
accumulative current value that starts from 0 for the connected servo amplifier is
stored.
• When of the absolute position detection system setting is valid, the accumulative
current value that starts from the absolute position command/encoder feedback
pulse for the connected servo amplifier is stored.
• The servo input axis current value will not change, even if an OPR or the current
value is changed.
Summary of Contents for LD77MH
Page 2: ......
Page 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Page 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Page 104: ...3 20 Chapter 3 Cam Function MEMO ...
Page 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Page 234: ...Appendix 18 Appendices MEMO ...
Page 237: ......