![Mitsubishi Electric LD77MH User Manual Download Page 157](http://html.mh-extra.com/html/mitsubishi-electric/ld77mh/ld77mh_user-manual_239045157.webp)
4 - 53
Chapter 4 Synchronous Control
[Cd.409] Synchronous control reflection time
Set the reflection time for synchronous control change processing as follows.
[Cd.407] Synchronous control change command
Setting details for
"[Cd.409] Synchronous control reflection time"
0: Cam reference position movement
The time to reflect the travel value to the cam
reference position.
1: Change cam axis current value per cycle
Setting not required.
2: Change current value per cycle after main shaft gear
3: Change current value per cycle after auxiliary shaft gear
4: Cam axis current value per cycle movement
The time to reflect the travel value to the cam axis
current value per cycle.