![Mitsubishi Electric LD77MH User Manual Download Page 117](http://html.mh-extra.com/html/mitsubishi-electric/ld77mh/ld77mh_user-manual_239045117.webp)
4 - 13
Chapter 4 Synchronous Control
4.1.4 Main shaft clutch control data
Setting item
Setting details
Setting value
Default
value
Buffer memory
address
[Cd.400]
Main shaft clutch
command
• Set the clutch command ON/OFF.
Fetch cycle: Operation cycle
Set in decimal.
0: Main shaft clutch command OFF
1: Main shaft clutch command ON
0 44080+20n
[Cd.401]
Main shaft clutch
control invalid
command
• Set "1" to disable the clutch control
temporarily.
Fetch cycle: Operation cycle
Set in decimal.
0: Main shaft clutch control valid
1: Main shaft clutch control invalid
0 44081+20n
[Cd.402]
Main shaft clutch forced
OFF command
• Set "1" to force the clutch OFF.
Fetch cycle: Operation cycle
Set in decimal.
0: Main shaft clutch normal control
1: Main shaft clutch forced OFF
0 44082+20n
n: Axis No.-1
[Cd.400] Main shaft clutch command
Use ON/OFF for the main shaft clutch command. This command is used with the following
settings.
• The clutch ON control mode is "1: Clutch command ON/OFF", "2: Clutch command
leading edge" or "3: Clutch command trailing edge".
• The clutch OFF control mode is either "2: Clutch command leading edge" or "3: Clutch
command trailing edge".
Status is considered as clutch command OFF just before starting synchronous control. If
synchronous control is started while the clutch command is ON, the condition is
established just after starting synchronous control, by setting "2: Clutch command leading
edge". The condition is not established just after starting, by setting "3: Clutch command
trailing edge".
[Cd.401] Main shaft clutch control invalid command
The main shaft clutch control is invalid if "1" is set. The previous clutch ON/OFF status
remains before clutch control becomes invalid.
Clutch control will not become invalid during the movement before clutch ON and clutch
OFF. Instead, clutch control will become invalid after movement is completed.
[Cd.402] Main shaft clutch forced OFF command
Set "1" to force the clutch OFF. The output value from the clutch becomes 0 immediately,
even during clutch smoothing. The slippage (accumulative) amount is set to 0 if smoothing
with a slippage method.
Reset to "0" to restart the clutch control from the clutch OFF status after using the clutch
forced OFF command.
Summary of Contents for LD77MH
Page 2: ......
Page 48: ...1 16 Chapter1 Outline of Synchronous Control MEMO ...
Page 84: ...2 36 Chapter 2 Input Axis Module MEMO ...
Page 104: ...3 20 Chapter 3 Cam Function MEMO ...
Page 168: ...4 64 Chapter 4 Synchronous Control MEMO ...
Page 234: ...Appendix 18 Appendices MEMO ...
Page 237: ......