![Mitsubishi Electric LD77MH User Manual Download Page 136](http://html.mh-extra.com/html/mitsubishi-electric/ld77mh/ld77mh_user-manual_239045136.webp)
4 - 32
Chapter 4 Synchronous Control
(6) High speed input request
The clutch is turned OFF when the high speed input request [DI] turns ON.
The following actions are required when using the high speed input request.
• Set the signal No. for the "High speed input request signal" clutch control setting.
• Set "4: High speed input request" in "[Pr.42] External command function selection"
and "1: Validates an external command" in "[Cd.8] External command valid" for the
applicable axis.
• For the 16-axis module, set the external command signal in "[Pr.95] External
command signal selection" for the applicable axis.
t
t
Cd.8 External command valid
Travel value after clutch
Current value before clutch
Clutch ON/OFF status
High speed input request [DI]