5 - 1
5. PARAMETERS
5. PARAMETERS
CAUTION
Never adjust or change the parameter values extremely as it will make operation
instable.
5.1 Parameter list
5.1.1 Parameter write inhibit
POINT
After setting the parameter No. 19 value, switch power off, then on to
make that setting valid.
This servo amplifier, its parameters are classified into the basic parameters (No. 0 to 19), expansion
parameters 1 (No. 20 to 49) and expansion parameters 2 (No.50 to 84) according to their safety aspects
and frequencies of use. In the factory setting condition, the customer can change the basic parameter
values but cannot change the expansion parameter values. When fine adjustment, e.g. gain adjustment,
is required, change the parameter No. 19 setting to make the expansion parameters write-enabled.
The following table indicates the parameters which are enabled for reference and write by the setting of
parameter No. 19. Operation can be performed for the parameters marked .
Parameter No. 19 setting
Operation
Basic parameters
No. 0 to No. 19
Expansion parameters 1
No. 20 to No. 49
Expansion parameters 2
No. 50 to No. 84
Reference
0000
(initial value)
Write
Reference
No. 19 only
000A
Write
No. 19 only
Reference
000B
Write
Reference
000C
Write
Reference
000E
Write
Reference
100B
Write
No. 19 only
Reference
100C
Write
No. 19 only
Reference
100E
Write
No. 19 only
Summary of Contents for GENERAL PURPOSE AC SERVO MR-E- A/AG
Page 1: ...General Purpose AC Servo MODEL MR E A AG INSTRUCTION MANUAL B ...
Page 11: ...A 10 MEMO ...
Page 17: ...6 MEMO ...
Page 31: ...2 4 2 INSTALLATION MEMO ...
Page 85: ...4 6 4 OPERATION MEMO ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO ...
Page 307: ...15 62 15 MR E AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT MEMO ...