3 - 35
3. SIGNALS AND WIRING
(2) For 1-phase 230VAC power supply
Power supply
1-phase 230VAC
Emergency stop
Servo-on
Servo amplifier
Trouble
Emergency
stop
External
power
supply
24VDC
RA
OFF
ON
MC
MC
SK
NFB
MC
L
1
L
2
L
3
EMG
SON
SG
VIN
ALM
SG
RA
(Note)
CNP1
P
D
C
Note: To use the built-in regenerative resistor, be sure to connect across P and D of the power supply connector (CNP1).
3.7.2 Terminals
Refer to Section 11.1 (4) for the signal arrangement.
Connected terminal
(Application)
Symbol
Description
Supply L
1
, L
2
and L
3
with the following power:
For 1-phase 230VAC, connect the power supply to L
1
/L
2
and leave L
3
open.
L
1
Servo amplifier
Power supply
MR-E-10A to
70A
MR-E-100A/
200A
L
2
3-phase 200 to 230VAC,
50/60Hz
L
1
L
2
L
3
1-phase 230VAC,
50/60Hz
L
1
L
2
Power supply
L
3
U
V
Servo motor output
W
Connect to the servo motor power supply terminals (U, V, W).
P
C
Regenerative brake
option
D
To use the built-in regenerative brake resistor of the servo amplifier, connect the
wiring across P-D of the power supply connector (CNP1).
When using the regenerative brake option, always remove the wiring from across
P-D and connect the regenerative brake option across P-C.
Refer to Section 13.1.1 for details.
Protective earth (PE)
Connect this terminal to the protective earth (PE) terminals of the servo motor
and control box for grounding.
Summary of Contents for GENERAL PURPOSE AC SERVO MR-E- A/AG
Page 1: ...General Purpose AC Servo MODEL MR E A AG INSTRUCTION MANUAL B ...
Page 11: ...A 10 MEMO ...
Page 17: ...6 MEMO ...
Page 31: ...2 4 2 INSTALLATION MEMO ...
Page 85: ...4 6 4 OPERATION MEMO ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO ...
Page 307: ...15 62 15 MR E AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT MEMO ...