4 - 1
4. OPERATION
4. OPERATION
4.1 When switching power on for the first time
Before starting operation, check the following:
(1) Wiring
(a) A correct power supply is connected to the power input terminals (L
1
, L
2
, L
3
) of the servo amplifier.
(b) The servo motor power supply terminals (U, V, W) of the servo amplifier match in phase with the
power input terminals (U, V, W) of the servo motor.
(c) The servo motor power supply terminals (U, V, W) of the servo amplifier are not shorted to the
power input terminals (L
1
, L
2
, L
3
) of the servo motor.
(d) The earth terminal of the servo motor is connected to the PE terminal of the servo amplifier.
(e) When using the regenerative brake option, the lead has been removed from across D-P of the servo
amplifier built-in regenerative brake resistor, and twisted cables are used for its wiring.
(f) When stroke end limit switches are used, the signals across LSP-SG and LSN-SG are on during
operation.
(g) 24VDC or higher voltages are not applied to the pins of connectors CN1.
(h) SD and SG of connectors CN1 are not shorted.
(i) The wiring cables are free from excessive force.
(2) Environment
Signal cables and power cables are not shorted by wire offcuts, metallic dust or the like.
(3) Machine
(a) The screws in the servo motor installation part and shaft-to-machine connection are tight.
(b) The servo motor and the machine connected with the servo motor can be operated.
Summary of Contents for GENERAL PURPOSE AC SERVO MR-E- A/AG
Page 1: ...General Purpose AC Servo MODEL MR E A AG INSTRUCTION MANUAL B ...
Page 11: ...A 10 MEMO ...
Page 17: ...6 MEMO ...
Page 31: ...2 4 2 INSTALLATION MEMO ...
Page 85: ...4 6 4 OPERATION MEMO ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO ...
Page 307: ...15 62 15 MR E AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT MEMO ...