12 - 3
12. CHARACTERISTICS
12.3 Dynamic brake characteristics
Fig. 12.3 shows the pattern in which the servo motor comes to a stop when the dynamic brake is operated.
Use Equation 12.2 to calculate an approximate coasting distance to a stop. The dynamic brake time
constant varies with the servo motor and machine operation speeds. (Refer to Fig. 12.4)
V
0
Time constant
Emergency stop(EMG)
OFF
ON
Machine speed
t
e
Time
Fig. 12.3 Dynamic brake operation diagram
L
max
60
V
0
J
L
J
M
t
e
1
....................................................................................................................... (12.2)
L
max
: Maximum coasting distance .................................................................................................[mm][in]
Vo
: Machine rapid feedrate ......................................................................................... [mm/min][in/min]
J
M
: Servo motor inertial moment................................................................................. [kg cm
2
][oz in
2
]
J
L
: Load inertia moment converted into equivalent value on servo motor shaft..... [kg cm
2
][oz in
2
]
: Brake time constant ........................................................................................................................ [s]
t
e
: Delay time of control section........................................................................................................... [s]
(There is internal relay delay time of about 30ms.)
0
14
16
2
4
8
10
6
12
0
500 1000 1500 2000 2500 3000
13
73
23
43
Speed [r/min]
Ti
me
c
o
n
s
ta
n
t
[
m
s
]
0
0.005
0.01
0.015
0.02
0.025
0.03
0.035
0.04
0.045
0
500
1000
1500
2000
202
102
152
52
Speed [r/min]
Tim
e
c
o
n
s
ta
n
t
[
s
]
a. HC-KFE series
b. HC-SFE series
Fig. 12.4 Dynamic brake time constant
Use the dynamic brake at the load inertia moment indicated in the following table. If the load inertia
moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility that the
load inertia moment may exceed the value, contact Mitsubishi.
Servo amplifier
Load inertia moment ratio [times]
MR-E-10A to MR-E-200A
30
Summary of Contents for GENERAL PURPOSE AC SERVO MR-E- A/AG
Page 1: ...General Purpose AC Servo MODEL MR E A AG INSTRUCTION MANUAL B ...
Page 11: ...A 10 MEMO ...
Page 17: ...6 MEMO ...
Page 31: ...2 4 2 INSTALLATION MEMO ...
Page 85: ...4 6 4 OPERATION MEMO ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO ...
Page 307: ...15 62 15 MR E AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT MEMO ...