13 - 21
13. OPTIONS AND AUXILIARY EQUIPMENT
13.2 Auxiliary equipment
Always use the devices indicated in this section or equivalent. To comply with the EN Standard or UL/C-
UL (CSA) Standard, use the products which conform to the corresponding standard.
13.2.1 Recommended wires
(1) Wires for power supply wiring
The following diagram shows the wires used for wiring. Use the wires given in this section or
equivalent.
C
P
U
V
W
B1
B2
U
V
W
L
1
L
2
L
3
D
Power supply
1) Power supply lead
Regenerative brake option
4) Regenerative brake option lead
(Note)
Servo amplifier
3) Motor power supply lead
5) Electromagnetic
brake lead
Encoder cable (refer to Section 13.1.2)
Motor
Electro-
magnetic
brake
Encoder
Servo motor
Note: When using the regenerative brake option, always remove the wiring across D-P.
The following table lists wire sizes. The wires used assume that they are 600V vinyl wires and the
wiring distance is 30m(98.4ft) max. If the wiring distance is over 30m(98.4ft), choose the wire size in
consideration of voltage drop.
Refer to Section 3.11 for connection with the connector (CNP1, CNP2).
The servo motor side connection method depends on the type and capacity of the servo motor. Refer to
Section 3.8.
To enable the built-in regenerative brake, connect the wiring across D-P. (Refer to Section 3.7.2 for the
connection method.)
To comply with the UL/C-UL (CSA) Standard, use UL-recognized copper wires rated at 60 (140 ) or
more for wiring.
Table 13.1 Recommended wires
(Note) Wires [mm
2
]
Servo amplifier
1) L
1
L
2
L
3
3) U
V
W
4) P
C
5) B1
B2
MR-E-10A
MR-E-20A
MR-E-40A
MR-E-70A
1.25 (AWG16)
MR-E-100A
2 (AWG14)
2 (AWG14)
MR-E-200A
(Note)
2.5 (AWG14)
(Note)
2.5 (AWG14)
2 (AWG14)
1.25 (AWG16)
Note: Use the heat-resistant PVC coble (more than 105
), if AWG14 cable is used in ambient temperature more than 40
.
Summary of Contents for GENERAL PURPOSE AC SERVO MR-E- A/AG
Page 1: ...General Purpose AC Servo MODEL MR E A AG INSTRUCTION MANUAL B ...
Page 11: ...A 10 MEMO ...
Page 17: ...6 MEMO ...
Page 31: ...2 4 2 INSTALLATION MEMO ...
Page 85: ...4 6 4 OPERATION MEMO ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO ...
Page 307: ...15 62 15 MR E AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT MEMO ...