15 - 54
15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
(2) Changing the status display screen
The status display item of the servo amplifier display shown at power-on can be changed by changing
the parameter No. 18 settings.
The item displayed in the initial status changes with the control mode as follows:
Control mode
Speed
Speed/torque
Torque
Status display at power-on
Servo motor speed
Servo motor speed/analog torque command voltage
Analog torque command voltage