APPX
Appendix 3 Buffer Memory
149
A
Temporarily reserved station specification request area
■
Temporarily reserved station specification request area (Un\G23608 to Un\G23611)
This area sets which DP-Slaves are to be specified as temporarily reserved stations by the temporarily reserved station
specification function.
• 0: Not specify the DP-Slave as a temporarily reserved station
• 1: Specifies the DP-Slave as a temporarily reserved station
The values in the table indicate which number of DP-Slave each bit represents.
Turning on 'Data exchange start request signal' (Un\G2.b0) causes DP-Slaves specified in 'Temporarily reserved station
specification request area' (Un\G23608 to Un\G23611) to be specified as temporarily reserved stations.
• Configure the values of 'Temporarily reserved station specification request area' (Un\G23608 to
Un\G23611) when 'Data exchange start request signal' (Un\G2.b0) is off. Any value configured while 'Data
exchange start request signal' (Un\G2.b0) is on will be ignored.
• Normal DP-Slaves can be switched into temporarily reserved stations. Reserved stations (DP-Slaves set as
reserved stations by slave parameters) cannot be switched into normal DP-Slaves.
For details on the temporarily reserved station specification function, refer to the following.
Page 39 Temporarily Reserved Station Specification Function
Address
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Un\G23608
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Un\G23609
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
Un\G23610
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
Un\G23611
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
Specify temporarily reserved stations
The temporarily reserved station specification function is executed
Stores the logical sum of 'Parameter setting status area (reserved station)' (Un\G23592 to Un\G23595) and 'Temporarily reserved station specification status
area' (Un\G23600 to Un\G23603)
OFF
ON
OFF
ON
'Temporary reserved station specification
request area' (Un\G23608 to Un\G23611)
'Data exchange start request signal'
(Un\G2.b0)
'Data exchange start completed signal'
(Un\G0.b0)
'Slave status area (reserved station setting
status)' (Un\G23048 to Un\G23051)
Summary of Contents for FX5-DP-M
Page 1: ...MELSEC iQ F FX5 User s Manual PROFIBUS ...
Page 2: ......
Page 9: ...7 MEMO ...
Page 12: ...10 INDEX 168 REVISIONS 170 WARRANTY 171 TRADEMARKS 172 ...
Page 13: ...11 CONTENTS ...
Page 19: ...1 DESCRIPTION 17 1 MEMO ...
Page 100: ...98 9 PROGRAMMING 9 2 DP Master settings DP Slave FDL address 2 ...
Page 101: ...9 PROGRAMMING 9 2 DP Master settings 99 9 DP Slave FDL address 3 ...
Page 108: ...106 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Page 109: ...9 PROGRAMMING 9 8 Program Example of the Global Control Function 107 9 ...
Page 110: ...108 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Page 112: ...110 9 PROGRAMMING 9 9 Program Example of Acyclic Communication Acyclic Communication ...
Page 114: ...112 9 PROGRAMMING 9 10 Program Example of the Alarm Acquisition Function ...
Page 169: ...APPX Appendix 4 Processing Time 167 A MEMO ...
Page 175: ......