APPX
Appendix 2 Standards
125
A
Caution for compliance with EC Directive
Caution for when the FX5-DP-M is used
When the FX5-DP-M is used, attach a ferrite core to the power supplies of the CPU module. Make 2 turns around the ferrite
core and attach within approximately 200 mm from the terminal block and connectors of the power cable. (Ferrite core used in
Mitsubishi Electric's test: E04SR401938 manufactured by SEIWA ELECTRIC MFG. CO., LTD.)
Caution for when the PROFIBUS cable is used
PROFIBUS cable is a shielded cable, so ground it at both ends. Strip a part of the jacket of the cable as shown below and
ground the exposed shield as much as possible.
Shield
Clamp metal fitting