8 PROFIBUS Configuration Tool
8.2 "PROFIBUS Configurator Tasks" Window
77
8
Slave Status
Checks the communication status of the PROFIBUS-DP network.
All the device addresses in the PROFIBUS-DP network are displayed, and the DP-Slave statuses are indicated by
corresponding colors.
Item
Description
0 to 125
Displays the DP-Slave status.
Number shown in each cell is a FDL address.
• Light gray: This FDL address is unused.
• Dark gray: This DP-Slave is set as a reserved station.
• Yellow: This DP-Slave has diagnostic information.
• Green: Data exchange is in progress.
• Red: Data exchange with the slave station has failed. Diagnostic information may be displayed in the "PROFIBUS Diagnosis" window.
By double-clicking a colored rectangle, the detailed information is displayed in a tooltip.
Cycle time
Displays the bus cycle time. (Unit: ms)
• Now: Current bus cycle time value
• Min: Minimum bus cycle time value
• Max: Maximum bus cycle time value
Start
Starts refresh of the window.
Stop
Stops refresh of the window.
Summary of Contents for FX5-DP-M
Page 1: ...MELSEC iQ F FX5 User s Manual PROFIBUS ...
Page 2: ......
Page 9: ...7 MEMO ...
Page 12: ...10 INDEX 168 REVISIONS 170 WARRANTY 171 TRADEMARKS 172 ...
Page 13: ...11 CONTENTS ...
Page 19: ...1 DESCRIPTION 17 1 MEMO ...
Page 100: ...98 9 PROGRAMMING 9 2 DP Master settings DP Slave FDL address 2 ...
Page 101: ...9 PROGRAMMING 9 2 DP Master settings 99 9 DP Slave FDL address 3 ...
Page 108: ...106 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Page 109: ...9 PROGRAMMING 9 8 Program Example of the Global Control Function 107 9 ...
Page 110: ...108 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Page 112: ...110 9 PROGRAMMING 9 9 Program Example of Acyclic Communication Acyclic Communication ...
Page 114: ...112 9 PROGRAMMING 9 10 Program Example of the Alarm Acquisition Function ...
Page 169: ...APPX Appendix 4 Processing Time 167 A MEMO ...
Page 175: ......