PURY-HP-T(S)NU-A, PURY-HP-Y(S)NU-A
MEES19K180
1
CONTENTS
Hyper Heating Inverter R2-Series
I.
Hyper Heating Inverter R2-Series
1. SPECIFICATIONS .................................................................................................................................... 2
2. EXTERNAL DIMENSIONS ....................................................................................................................... 14
3. CENTER OF GRAVITY ............................................................................................................................ 20
4. ELECTRICAL WIRING DIAGRAMS ......................................................................................................... 21
5. SOUND LEVELS ...................................................................................................................................... 23
5-1. Sound levels in cooling mode .......................................................................................................... 23
5-2. Sound levels in heating mode.......................................................................................................... 25
6. VIBRATION LEVEL .................................................................................................................................. 27
7. OPERATION TEMPERATURE RANGE................................................................................................... 28
8. CAPACITY TABLES ................................................................................................................................. 29
8-1. Selection of Cooling/Heating Units .................................................................................................. 30
8-2. Correction by temperature ............................................................................................................... 40
8-3. Correction by total indoor................................................................................................................. 64
8-4. Correction by refrigerant piping length............................................................................................. 67
8-5. Correction at frost and defrost ......................................................................................................... 70
8-6. Correction at evaporation-temperature (ET) control ........................................................................ 70
9. OPTIONAL PARTS................................................................................................................................... 71
9-1. JOINT and REDUCER..................................................................................................................... 71
9-2. OUTDOOR TWINNING KIT............................................................................................................. 75
9-3. JOINT KIT "CMY-R160-J1" FOR BC CONTROLLER ..................................................................... 76
10.ELECTRICAL WORK ............................................................................................................................... 77
10-1.General cautions ............................................................................................................................. 77
10-2.Power supply for Outdoor unit ......................................................................................................... 78
10-3.Power cable specifications .............................................................................................................. 79
10-4.Power supply examples................................................................................................................... 80
11.M-NET CONTROL ................................................................................................................................... 82
11-1.Transmission cable length limitation................................................................................................ 82
11-2.Transmission cable specifications ................................................................................................... 83
11-3.System configuration restrictions..................................................................................................... 84
11-4.Address setting................................................................................................................................ 88
12.PIPING DESIGN ...................................................................................................................................... 100
12-1.R410A Piping material..................................................................................................................... 101
12-2.Piping Design .................................................................................................................................. 103
12-3.Refrigerant charging calculation ...................................................................................................... 110
12-4.Compatibility .................................................................................................................................... 114
13.OUTDOOR INSTALLATION .................................................................................................................... 115
13-1.General requirements for installation............................................................................................... 115
13-2.Spacing............................................................................................................................................ 116
13-3.Piping direction ................................................................................................................................ 118
13-4.Weather countermeasure ................................................................................................................ 123
13-5.Countermeasure to wind ................................................................................................................. 123
0000005744.BOOK 1 ページ 2020年2月25日 火曜日 午後5時19分