background image

Page 1 

 

EH1614 / EU 

 2.3kW (8000 BTU/hour)  

Portable Air Conditioner 

Climatiseur Local 

Summary of Contents for EH1614/EU

Page 1: ...Page 1 EH1614 EU 2 3kW 8000 BTU hour Portable Air Conditioner Climatiseur Local...

Page 2: ...pliance contains a refrigerant gas so must be kept upright at all times After unpacking wait 3 hours for the refrigerant gas to stabilise before use The following is a list of parts that should be inc...

Page 3: ...vented off with the hot exhaust air If you wish the condensate tank can be permanently connected to the drain To do this a long drain tube may be attached to the drain port and ran to a suitable drain...

Page 4: ...pwards Expand a small section of the other end of the hose and screw into joint B again in a clockwise direction Attach the indoor adaptop Joint A to the rear exhaust vent by sliding the adaptor into...

Page 5: ...Do not allow the hose to be crushed The hose can be expanded up to 1 5m long but the shorter it is the more efficiently the E1614 will operate Do not extend the hose or replace with another type of h...

Page 6: ...it is mandatory for new buildings PRODUCT SAFETY This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experie...

Page 7: ...ght position Do not allow the appliance to fall over when there is water in the bucket PAT TESTING When used in an office environment we recommend that this product should be safety tested yearly by a...

Page 8: ...it and control panel will display the desired temperature 16 C 30 C and the cool mode indicator light will illuminate The temperature can be adjusted using the buttons In dry mode the display will be...

Page 9: ...utton will increase or decrease the time to start or switch off See TIMER section for more information 4 FAN This button will adjust the fan speed in both FAN and COOL modes There are 3 fan speeds and...

Page 10: ...r button to confirm the T ON and H icons will stop flashing The unit will now switch ON after the selected time has elapsed Switching the unit OFF or ON manually will cancel the TIMER 7 CHILD LOCK Pre...

Page 11: ...or solvents b Clean and remove any dust and dirt from the louvers and air outlets Filter Cleaning Clean the filter every two weeks as the condition of the filters will inhibit the efficient operation...

Page 12: ...heating mode Change the set temperature Poor cooling performance There is direct sunlight in the room Close the window curtains blinds The doors and windows are open the room is crowded or there are o...

Page 13: ...pipes and filters 2 Turn the units OFF and wait 10 mins 3 Turn the unit ON if the problem persists contact an authorised repair agent H3 1 Ambient Temperature is too High 2 The evaporator or Condensor...

Page 14: ...ng modes and 0 05 per hour to run in the fan only mode To minimise the power used and reduce operating costs Make sure that the filter is kept clean Make sure that the air intakes and exhausts are not...

Page 15: ...Rated Current Cooling A 4 2 EER for Cooling R410A W W 2 6 Moisture Removal L h 0 75 Air Circulation m h 330 Noise High dB A 54 Middle dB A 52 Low dB A 50 Product Size W H D mm 300 800 355 Packing Siz...

Reviews: