(2) Heating operation
Operation
Outdoor unit model
PUHY-P500YSHM-A
Operating
conditions
Ambient
tempera-
ture
Indoor
DB/WB
20°C/ - [68°F/ - ]
Outdoor
7°C/6°C [45°F/43°F]
Piping
Main pipe
m [ft]
7.5 [24-3/5]
Branch pipe
-
Total pipe length
7.5 [24-3/5]
Outdoor
unit
Electric current
A
27.6
Voltage
V
380
Compressor frequency
Hz
107
LEV open-
ing
Indoor unit
Pulse
684
SC (LEV1)
0
LEV2
732
Pressure
High pressure (after O/S)/low
pressure (before accumulator)
MPa
[psi]
3.06/0.55 [444/80]
Temp. of
each sec-
tion
Outdoor
unit
Discharge (TH4)
°C [°F]
85 [185]
Heat exchanger out-
let (TH3)
0 [32]
Accumulator inlet
-6 [21]
Accumulator outlet
-6 [21]
Compressor inlet
-6 [21]
Compressor shell
bottom
26 [79]
Indoor
unit
LEV inlet
30 [86]
Heat exchanger
outlet
74 [165]