3. POSITIONING SIGNALS
3
−
54
(6) Servo amplifier loading information
(D9191 to D9192)........................................................Data from PCPU to SCPU
When the servo system CPU control power supply (A6 P) is switched on or
reset, the servo amplifier and option slot loading states are checked and its
results are stored.
The axis which turned from non-loading to loading status after power-on is
handled as loaded. However, the axis which turned from loading to non-loading
status remains as loaded.
Sarvo amplifier loading status
Loaded 1
Non-loaded 0
Axis16
D9191
D9192
Axis15
Axis14
Axis13
Axis12
Axis11
Axis10
Axis9
Axis8
Axis7
Axis6
Axis5
Axis4
Axis3
Axis2
Axis1
Axis32
Axis31
Axis30
Axis29
Axis28
Axis27
Axis26
Axis25
Axis24
Axis23
Axis22
Axis21
Axis20
Axis19
Axis18
Axis17
b15 b14 b13 b12 b11 b10
b9
b8
b7
b4
b3
b2
b1
b0
b6
b5
(a) Servo amplifier installation status
1) Installed/not installed status
•
"installed" status............... The MR- -B is normal
(i.e. communication with the servo amplifier is
normal)
•
"not installed" status......... No servo amplifier is installed.
The servo amplifier power is OFF.
Normal communication with the servo
amplifier is not possible due, for example, to a
connecting cable fault.
2) The system settings and servo amplifier installation statuses are
indicated below.
ADU
MR-
-B
System Settings
Loaded
Not loaded
Loaded
Not loaded
Used (axis No. setting)
1 is stored
Major error
1 is stored
0 is stored
Unused
0 is stored
0 is stored
0 is stored
0 is stored
(7) PC link communication error code (D9196)
When an error occurs during PC link communication, the error code that
corresponds to the error is stored in this device.
PC Communication Error Code
Storage Register
Contents
D9196
00: No error
01: Receiving timing error
02: CRC error
03: Communication response code error
04: Receiving flame error
05: Communication task start error
(Each error code is reset to 00 when
normal communication is restarted.)
For details of PC link communication errors, see Appendix 2.5.