![Mitsubishi Electric A173UHCPU Programming Manual Download Page 65](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567065.webp)
3. POSITIONING SIGNALS
3
−
34
(3) Control change registers
Axis
No.
Device Number
Signal Name
1
D640, D641
2
D642, D643
Refresh cycle
Import cycle
3
D644, D645
Signal Name
Number of set axes
Number of set axes
4
D646, D647
A173UHCPU
1 to 20
21 to 32
1 to 20
21 to 32
5
D648, D649
SV13
A273UHCPU
1 to 12
13 to 24
25 to 32
1 to 12
13 to 24
25 to 32
6
D650, D651
A173UHCPU
1 to 12
13 to 24
25 to 32
1 to 12
13 to 24
25 to 32
7
D652, D653
SV22
A273UHCPU
1 to 8
9 to 18
19 to 32
1 to 8
9 to 18
19 to 32
Unit
Signal
direction
8
D654, D655
9
D656, D657
0
1
JOG speed setting register
At start
Command
unit
SCPU
→
PCPU
10
D658, D659
11
D660, D661
12
D662, D663
13
D664, D665
14
D666, D667
15
D668, D669
16
D670, D671
17
D672, D673
18
D674, D675
19
D676, D677
20
D678, D679
21
D680, D681
22
D682, D683
23
D684, D685
24
D686, D687
25
D688, D689
26
D690, D691
27
D692, D693
28
D694, D695
29
D696, D697
30
D698, D699
31
D700, D701
32
D702, D703