7. POSITIONING CONTROL
7
−
7
7.1.3
Control units for 1-axis positioning control
Positioning control of 1-axis is conducted in the control units designated in the fixed
parameters.
(The control unit designation in the parameter block is ignored.)
7.1.4
Control units for interpolation control
(1) The interpolation control units designated in the parameter block are checked
against the control units designated in the fixed parameters.
For interpolation control, the result of the interpolation control units designated
in the parameter block differing from the control units designated in the fixed
parameters are listed in the following table.
Interpolation Control Units in Parameter Block
mm
inch
degree
PULSE
Start Method
Normal start
conditions
Fixed parameters
designate mm and inch
control units for axis.
Fixed
parameters
designate
degree control
units for axis.
Fixed
parameters
designate pulse
control units for
axis.
Control started using interpolation control units
designated in the parameter block.
Unit
discrepancy
error (Error
code 40)
Discrepancy between fixed parameter control units and the
parameter block interpolation control units for all axes.
!
Control started using set control units when
control units match for axis under interpolation
control.
!
Control started using the control units with the
highest order of priority (see below) when control
units differ for axis under interpolation control.
Order or priority
PLS > degree > inch > mm
<Example>
If axis is set to 1000 PLS and 10.000 inch, the
10.000 inch setting is considered to be 10,000
PLS.
(2) The possible combinations of control units for interpolation control for the axis is
shown in the table below.
mm
inch
degree
PULSE
mm
1)
2)
3)
3)
inch
2)
1)
3)
3)
degree
3)
3)
1)
3)
PULSE
3)
3)
3)
1)
Remarks
1) Same units
2) Combination of mm and
inches
3) Discrepancy
(a) Same units (1))
Positioning is conducted using position commands calculated from the
address, travel value, positioning speed, and electronic gear.
POINT
(1) Circular interpolation control
If control units for one axis are degrees, use degrees also for the other
axis.