3. POSITIONING SIGNAL
3
−
3
(2) Axis statuses
Axis
No.
Device
Number
Signal Name
1
M2400 to M2419
2
M2420 to M2439
Refresh cycle
Import cycle
3
M2440 to M2459
Signal name
Number of set axes
Number of set axes
4
M2460 to M2479
A173UHCPU
1 to 20 21 to 32
1 to 20 21 to 32
5
M2480 to M2499
SV13
A273UHCPU
1 to 12 13 to 24 25 to 32 1 to 12 13 to 24 25 to 32
6
M2500 to M2519
A173UHCPU
1 to 12 13 to 24 25 to 32 1 to 12 13 to 24 25 to 32
7
M2520 to M2539
SV22
A273UHCPU
1 to 8
9 to 18 19 to 32
1 to 8
9 to 18 19 to 32
Signal
direction
8
M2540 to M2559
0
Positioning start completion
9
M2560 to M2579
1
Positioning completion
10
M2580 to M2599
2
In-position
11
M2600 to M2619
3
Command in-position
12
M2620 to M2639
4
Speed controlling
13
M2640 to M2659
5
Speed-position switching latch
14
M2660 to M2679
6
Zero point passage
3.5ms 7.1ms
14.2ms
15
M2680 to M2699
7
Error detection
Immediate
16
M2700 to M2719
8
Servo error detection
3.5ms
7.1ms 14.2ms
17
M2720 to M2739
9
Zeroing request
10ms
20ms
18
M2740 to M2759
10 Zeroing completion
3.5ms
7.1ms 14.2ms
19
M2760 to M2779
11 External signal FLS
20
M2780 to M2799
12 External signal RLS
21
M2800 to M2819
13 External signal STOP
22
M2820 to M2839
14 External signal DOG
10ms
20ms
23
M2840 to M2859
15 Servo ON/OFF status
24
M2860 to M2879
16 Torque limiting signal
3.5ms
7.1ms 14.2ms
25
M2880 to M2899
17 External signal CHANGE
10ms
20ms
26
M2900 to M2919
18 User unusable
27
M2920 to M2939
19 M-code outputting signal
3.5ms
7.1ms 14.2ms
SCPU
←
PCPU
28
M2940 to M2959
29
M2960 to M2979
30
M2980 to M2999
31
M3000 to M3019
32