APPENDICES
APP
−
32
Table 2.12 Servo Amplifier Error List (2000 to 2799) (Continued)
Error Cause
Error
Code
Amplifier
Type
Name
Description
When Error Checked
Error Processing
Corrective Action
•
The parameter setting is wrong.
•
The parameter data was corrupted.
2601
Amplifier setting
2602
Regenerative resistance
2603
Motor type
2604
Motor capacity
2605
Motor rpm
2606
Number of feedback
pulses
2607
Rotating direction
setting
2608
Automatic tuning setting
2609
Servo responsibility
2610
Torque limit (forward)
2611
Torque limit (reverse)
2612
Load inertia ratio
2613
Position control gain 1
2614
Speed control gain 1
2615
Position control gain 2
2616
Speed control gain 2
2617
Speed integral
compensation
2618
Notch filter
2619
Feed forward coefficient
2620
In-position range
2621
Electromagnetic brake
sequence output
2622
Monitor output mode
selection
2623
Optional function 1
2624
Optional function 2
2625
Optional function 3
2626
Optional function 4
2627
Monitor output 1 offset
2628
Monitor output 2 offset
2629
Pre-alarm data
selection
2630
Zero speed
2631
Excessive error alarm
level
3632
Optional function 5
3633
Optional function 6
2634
PI-PID switching
position droop
2635
Torque limit
compensation factor
2636
Speed integral
compensation (real
speed differential
compensation)
2601
to
2636
M
Initial parameter
alarm
•
At power-on of servo
amplifier
•
On PLC ready (M2000)
leading edge
•
At servo error reset
•
At power-on of servo
system CPU
Immediate stop
•
After checking and correcting the
parameter setting, turn the servo
system CPU power OFF, then ON,
reset the servo system CPU with the
key, or turn PLC ready (M2000) OFF,
then ON.