12. Usage
MiR250 Shelf Carrier User Guide (en) 03/2021 - v.1.4 ©Copyright 2021: Mobile Industrial Robots A/S.
193
5.
In the Mute protective fields action, set the parameters as follows:
•
Sound:
Select
Default
•
Front:
Create a variable titled
Mute fields
.
•
Rear:
Create a variable titled
Mute fields
.
•
Sides:
Create a variable titled
Mute fields
.
MiR250 Shelf Carrier cannot mute specific Protective fields; you can either
mute all or none of the fields. Otherwise, the robot reports an error. If you
use a variable with the same name in all parameters, you ensure that you
apply the same parameter setting to all.